This method statement covers surface preparation, priming, plural-component hot-spray application and quality control of PETROUREA pure polyurea coatings on concrete and steel, for roof and deck waterproofing, tanks and bunds, and industrial surfaces.
Grade, thickness and primer are selected per project for immersion, chemical, temperature, UV and mechanical exposure; chemical media and immersion limits must be confirmed for each project.
Key specifications
Values shown are taken from the published brochure/TDS. Project acceptance follows the approved batch certificate and consultant specification.
- Document
- PS-MS-05, 3 pages
- System
- PETROUREA 300–800 pure polyurea, plural-component hot spray
- Hose temperature
- Typically 70 – 85 °C
- Mix ratio
- 1 : 1 by volume unless the grade data states otherwise
- Surface preparation
- Concrete shot-blast (ICRI CSP 3–5); steel blasted to ISO 8501-1 Sa 2½
- Environment
- Substrate at least 3 °C above dew point
- Testing
- Thickness grid, holiday test (immersion areas), pull-off adhesion
Applications
- — Seamless roof and deck waterproofing
- — Industrial tanks and bunds
- — Steel structures under mechanical stress
Referenced standards
ISO 8501-1 · ICRI 310.2R · ASTM D4541 · ASTM D7234